Detection of bronchial intraepithelial neoplasia in uranium miners by Systém Autofluorescence Endoscopy (SAFE- 1000)
Horváth Teodor, Horváthová Marie, Salajka František 1 , Habanec Boris 2 , Pafko Pavel 3 , Kaňa Jindřich 4 ,
Wurst František 5 , Foretová Lenka, Koukalová Hana, Novotná Eva, Pecina Josef, Vagunda Václav, Vrbacký Roman, Talač Robert, Čoupková Helena, Pačovský Zdeněk
|
|
Summary:
The occurrence of premalignant changes of bronchial epithelium was studied in 56 symptom-free volunteers from the risk group
of Czech and Moravian uranium miners (mean age 50.69 years, mean WLM 21.06) by the additional employment of the System of
Autofluorescence Endoscopy (SAFE-1000 Pentax) to conventional white-light bronchoscopy, comparing results with those of
bronchial biopsy histopathology examination. Histopathology using hematoxylin and eosin staining confirmed intraepithelial
neoplasias in 15 areas in 10 persons. White-light bronchoscopy sensitivity was 21.05%, and specificity 93.7% which an autofluo-
rescence sensitivity was 78.95%, and specificity 81.89%.
1 Working Level Month (WLM) = the absorption of latent energy of 2.08 x 10 -5 J/m 3 in one month (i.e. 170 working hours).
Key words:
autofluorescence bronchoscopy, bronchial (pre-)neoplasia, bronchogenic cancer, uranium miner
|