General Anaesthesia with Laryngeal Mask Airway PAVLÍK M., BARTOŠÍK T., HŘIB R., NOHEL P., ŽÁK J. 1 1 Anesteziologicko-resuscitační klinika, Fakultní nemocnice u svaté Anny v Brně, přednosta doc. MUDr. Pavel Ševčík, CSc. |
|
Summary: Laryngeal mask airway represents a simple, effective and safe way to secure the airway during general anaesthesia. In the hands of an experienced
anaesthesiologist, its insertion is safe even in different positions of a patient. LMA can be used for both spontaneous and positive pressure ventilation.
The complication rate with LMA compared to standard tracheal intubation is not higher, and t he complications appear to be less critical.
|
|
|