CZECH MEDICAL ASSOCIATION J. Ev. PURKYNĚ | |
Journals - Article | |
Česky / Czech version | Čes. Radiol., 56, 2002, No. 3, p. 184-187 |
Endovascular Treatment of Dissection of the Aorta Type B: Care-record of an Uncommon Complication Raupach J.1, Lojík M.1, Krajina A.1, Dominik J.2, Brzek V2, Polanský P2 Radiologická klinika FN, Hradec Králove, přednosta doc. MLJDr. P Eliáš, CSc. Kardiochirurgická klinika FN, Hradec Králové,2 přednosta prof. MLJDr. J. Dominik |
|
Summary: The authors present an unusual Complication of endovascular treatment of the thoracic aorta dissection B. Stent-graft placement finto the descending thoracic aorta initiated a false-lumen thrombosis by sealing of the proximal entry. In this tase authors used the thoracic stem-graft and at the same time the uncovered stem for dilatation of stenotic trne lumen. The ascending aorta was either injured during endovascular procedura or spontaneously. Stent-graft and bare stem placement induced successfully the false-lumen thrombosis and dilatation of the trne lumen. After three months the patient is in a good condition without any symptoms and CT revealed thrombosis of the false lumen in the ascending thoracic aorta.
|
|
Order this issue
|
BACK TO CONTENTS | ||
| HOME PAGE | CODE PAGE | CZECH VERSION | |
© 1998 - 2008 CZECH MEDICAL ASSOCIATION J. E. PURKYNĚ |
Created by: NT Servis, s.r.o., hosted by P.E.S. consulting, s.r.o. |
WEBMASTER |