CzMA JEP Home page CZECH MEDICAL ASSOCIATION J. Ev. PURKYNĚ
Journals - Article
CzMA JEP Home page News About Assocation Publishing Division Medical Journals Searching Supplements Catalogue
 
  Česky / Czech version Prakt. zub. Lék., roč. 54, 2006, č. 5, s. 87-90.
 
The Effect of the Hand and the Power Driven Rott Canal Rinse 
Jurisa M., Roubalíková L. 

Stomatologická klinika LF MU a FN u sv. Anny, Brno, přednosta prof. MUDr. J. Vaněk, CSc.
 


Summary:

       The authors compare the effect of the various methods of the rinse of the root canal. 12 extracted single root teeth were randomly dividend into 3 groups. The endodontic treatment was performed using hand instruments under standard conditions (EDTA gel in combination with 2% NaOCl). In the first group only hand rinsing was preformed, in the second group the special endodontic canila was used ane in the third group the power driven instrument Rinse Endo, DürrDental, Germany) was used. After the preparation the teeth were split longitudinaly and microscopically observed. The clean areas were quantified and the groups were compared statistically with the Fischer exact test (p=0,05). The cleanliness of the root canal walls was significantly better in the group where Rinse Endo was used.

        Key words: rinsing of the root canal — cleanliness of the root canal walls — smear layer
       

Order this issue

  BACK TO CONTENTS  
 
 
| HOME PAGE | CODE PAGE | CZECH VERSION |
©  1998 - 2008 CZECH MEDICAL ASSOCIATION J. E. PURKYNĚ
Created by: NT Servis, s.r.o., hosted by P.E.S. consulting, s.r.o.
WEBMASTER