Tracheal Rupture during Orotracheal Intubation in General Anesthesia – a Case Report MRÁZOVÁ M., HERIBAN P. ARO Městské nemocnice Mariánské Lázně, primář MUDr. P. Heriban |
|
Summary: After induction of general anesthesia, orotracheal intubation was performed. The signs of ruptured trachea occured soon afterwards. This is a rare
complication of intubation if a stylet is not used or if prolonged intubation is not the case. The complication was immediately successfully managed.
|
|