Česky / Czech version | Soud. Lék., 43, 1998, No. 4, p. 58 - 64 |
Proof and Detection of Abused Opiates in Urine and Blood of Fatal Cases thin Layer Chromatography with Densitometry J. Valuch, M. Bauer * Ústav súdneho lekárstva LF UK a FN, Bratislava, prednosta doc. MUDr. M. Mego, CSc. * Laboratórium súdnej chémie a toxikológie LF UK, Bratislava, vedúci doc. RNDr. M. Bauer, CSc. |
|
Summary: Urine and blood concentrations of free and total morphin or 6-monoacetylmorphin were presen- ted in fatal cases of morphin type opiates abuse. A solid phase extraction method was developed for isolation of drugs and their metabolities from biological material which used Separcol small columns with non-polar contents SI C 18T. Thin layer chromatography with densitometry anabled screening for quality evaluations. Resultes were compared with those obtained by fluoropolari- zing immunodetection on Abbotts TDxFLx device. Posibility and cause of false positive results were discussed when using initial, screening, commercialy available immunotests.
|
|