  Česky / Czech version Soud. Lék., 43, 1998, No. 4, p. 58 - 64
 
Proof and Detection of Abused Opiates in Urine and Blood of Fatal Cases thin Layer Chromatography with Densitometry 
J. Valuch, M. Bauer * 

Ústav súdneho lekárstva LF UK a FN, Bratislava,
prednosta doc. MUDr. M. Mego, CSc.
* Laboratórium súdnej chémie a toxikológie LF UK, Bratislava,
vedúci doc. RNDr. M. Bauer, CSc.
 


Summary:

       Urine and blood concentrations of free and total morphin or 6-monoacetylmorphin were presen- ted in fatal cases of morphin type opiates abuse. A solid phase extraction method was developed for isolation of drugs and their metabolities from biological material which used Separcol small columns with non-polar contents SI C 18T. Thin layer chromatography with densitometry anabled screening for quality evaluations. Resultes were compared with those obtained by fluoropolari- zing immunodetection on Abbotts TDxFLx device. Posibility and cause of false positive results were discussed when using initial, screening, commercialy available immunotests.

        Key words: drug abuse - drug screening - morphin - 6-monoacetylmorphin - solid phase SI C 18T extraction - thin layer chromatography - densitometry - immunometods
       

Order this issue

  BACK TO CONTENTS  
 
 
| HOME PAGE | CODE PAGE | CZECH VERSION |
©  1998 - 2008 CZECH MEDICAL ASSOCIATION J. E. PURKYNĚ
Created by: NT Servis, s.r.o., hosted by P.E.S. consulting, s.r.o.
WEBMASTER