Summary:
Purpose: Despite of decreasing incidence of the PCO, this is still a major and
frequent complication of cataract surgery and IOL implantation. Therefore, in
our Department, we pay currently intense attention to the PCO problem. The
introduction of EAS 1000 in October 2001 allowed us to analyze exactly the
relevant PCO issues and our attitude toward its treatment as well. The purpose
of our study was to compare the PCO degree in eyes with implanted either
PMMA IOLs with round edges or hydrophilic acrylate IOLs with sharp edges.
Four types of IOLs were compared in our trial.
Materials and methods: In the Department of Ophthalmology, Comenius
University and Faculty Hospital, Bratislava, Slovakia, the PCO development
was analyzed in patients operated on due to senile cataract between November
14th 2001 and April 10th 2003. Eighty-two eyes of 77 patients were followed-up
from November 2001 till April 2006.
During the 36 months’ follow-up, 82 eyes of 77 patients were enrolled in this
study.We evaluated the PCO at day 1, week 1 and 3, 6, 12, 24, and 36 months after
the cataract surgery. In all patients, the best visual acuity was assessed. The
photographs of the posterior capsule in retro-illumination in the widest
possible mydriasis were obtained and evaluated by means of EAS 1000.
Results: Our study revealed significant influence of the optic material and the
type of the implant edge on the PCO development. We did not find any
correlation between the visual acuity and the transparency of the posterior
capsule. The incidence of Nd:YAG-laser capsulotomies was similar in the two
compared IOL groups (PMMA round edged vs. hydrophilic acrylate sharp
edged IOLs). We also did not find any correlation between the size of area
evaluated and the posterior capsule transparency.
Conclusion: In our experience, EAS 1000 (NIDEK) has proved to be a suitable
device for the follow up of the PCO development following various IOLs types
implantation in both experimental and clinical setting. Standardized and
objective evaluation systems based on the retro-illumination photography are
needed. Despite a certain possibility of examiner-related error of measurement,
EAS 1000 (NIDEK) is an accurate device for PCO evaluation.
Key words:
posterior capsule opacification, intraocular lens, EAS 1000 eye
analyzing system, polymethylmetacrylate, hydrophilic acrylate
|