CzMA JEP Home page CZECH MEDICAL ASSOCIATION J. Ev. PURKYNĚ
Journals - Article
CzMA JEP Home page News About Assocation Publishing Division Medical Journals Searching Supplements Catalogue
 
  Česky / Czech version Čes.-slov. Pediat., 2005, roč. 60, č. 11, s. 599–605.
 
Reliability of Noninvasive Measurement of Bilirubin Concentration in Healthy Newborns 
Maťašová K., Zibolen M., Čiljak M., Kolarovszká H., Murgaš D.1, Baška T.2 

Neonatologická klinika JLF UK a MFN, Martin prednosta prof. MUDr. M. Zibolen, CSc. Klinika detskej chirurgie JLF UK a MFN, Martin1 prednosta doc. MUDr. M. Dragula, CSc., mim. prof. Ústav verejného zdravotníctva, Oddelenie epidemiológie JLF UK, Martin2 vedúci MUDr. T. Baška, PhD.
 


Summary:

       Objective: To evaluate reliability of transcutaneous measurement of bilirubin (Bi) concentration using a noninvasive bilirubinmeter Air-Shields Minolta JM-103 and to compare the results obtained on various parts of the newborn body surface. Patients and methods: The whole cohort („s“) of 247 physiological newborns (139 boys, 108 girls) was divided according to concentration serum Bi into a physiological subgroup „f“ (Bi <220 µmol/l, n = 138) and a pathological subgroup „p“ (Bi ≥220 µmol/l, n = 109). Results: Differences (∆) between the transcutaneous value of Bi concentration on the forehead (∆C), sternum (∆S), belly (∆B) and the value of Bi concentration in serum, considered as standard, were evaluated. Insignificant differences in the subgroup „f“ were obtained in the measurement on the forehead (∆C = 1.25 µmol/l (CI –3.1–5.6)) and in the subgroup „p“ on sternum (∆S = 1.9 µmol/l (CI –-3.7–7.5)) as well as on the belly (∆B = 3.4 (CI–-3.2–10.0)), (p >0.05), the other observed differences in both subgroups „f“, „p“ as well as in the whole cohort „s“ displayed significant differences as compared to serum concentration of Bi. Conclusion: Based on the results it is possible to recommend transcutaneous measurement of Bi concentration by the apparatus Minolta JM-103 in the area of sternum or belly of mature newborns as a reliable examination, which safely diagnoses hyperbilirubinemia where therapy is required.

        Key words: newborn, bilirubin, hyperbilirubinemia, icterus, transcutaneous measurement, Minolta JM-103
       

Order this issue

  BACK TO CONTENTS  
 
 
| HOME PAGE | CODE PAGE | CZECH VERSION |
©  1998 - 2008 CZECH MEDICAL ASSOCIATION J. E. PURKYNĚ
Created by: NT Servis, s.r.o., hosted by P.E.S. consulting, s.r.o.
WEBMASTER