Covered Iatrogenic
Arterial Perforation after Prolongation Osteotomy
Žižkovská K., Kolář J., Štrof J., Kubeš R. Radiodiagnostická klinika IPVZ, Fakultní nemocnice Praha-Bulovka, přednostka prof. MUDr. J. Bohutová, DrSc. Klinika ortopedické chirurgie IPVZ, Fakultní nemocnice Praha-Bulovka, přednosta prof. MUDr. P. Dungl, DrSc. |
|
Summary: The authors describe the observation of a covered arterial perforation after application of external
fixation device in a female patient following prolongation osteotomy of the leg. They drawattention
to this possible iatrogenic complication which may be serious and calls for a surgical solution.
|
|
|