Summary:
Endocapsular distance ring increases possibilities of extraction subluxated cata-
ract. Its importance consists of stabilisation of capsular bag and with the possibi-
lity of implantationposterior intraocular lens.
In the group there are 20 patients with implantated 21 distance rings. The period
of follow up was 4-24 months. We used of a polymethyl methacrylate distance ring
from firms Erilens, Morcher and IOLTechnology. Indication for the implantation
of a distance ring was dialysis less than 2 quadrants, it depends on size and type
of distance ring. The authors evaluate complications during the operation and
early and later results after operation.
Key words:
endocapsular distance ring, extraction of subluxated cataract, dialysis
of the zonula
|