Summary:
Authors evaluated postoperative refractive errors after implantation of intraocu-
lar lens at the set of 429 eyes.There predominated eyes with short axial lenght
(AL)at this set:304 eyes had AL <22 mm,average AL was 21,54 mm.The basic
point was to correct the linearity of SRK formula by different way from SRK II
formula,while keeping the new formula simple to use.Authors reached following
modification of A-constant in SRK formula:new A-constant =original A-constant
+C,where C =0,146*AL 2 -7,702*AL +100,130.
Key words:
biometry,short axial lenght,IOL calculation formula
|