CZECH MEDICAL ASSOCIATION J. Ev. PURKYNĚ | |
Journals - Article | |
Česky / Czech version | Čes. Stom., roč. 104, 2004, č. 1, s. 3–8. |
Profilometric Analysis on the Surface of Composite Materials Pírek P., Kopřiva M. II. stomatologická klinika LF UP, Olomouc, přednosta prof. MUDr. M. Eber, CSc. Společná laboratoř optiky Univerzity Palackého a Fyzikálního ústavu AV ČR, Olomouc, vedoucí doc. RNDr. M. Hrabovský, DrSc. |
|
Summary: The optimum way to polish composite materials in the physician’s consulting
room and in the dental laboratory remains an open question. The authors analyzed the surface
of samples of laboratory composites after polishing. Different ways of polishing of the hybrid
glass polymer Artglass and a more recent microfilled glass polymer Signum produced by
Heraeus-Kulzer were compared. The roughness of surface was measured by the method of
Atomic Force Microscopy (AFM). At the level of AFM the microfilled glass polymer Signum
proved to be polished better than the Artglass material. In the samples of glass polymer
composite Artglass polished with the Opal paste or a combination of the HP paste and the
polishing suspension Sitol, better results were reached than with the polishing by the HP paste
recommended by the producer. The time polishing played a positive role in the quality of
polished sample.
|
|
Order this issue
|
BACK TO CONTENTS | ||
| HOME PAGE | CODE PAGE | CZECH VERSION | |
© 1998 - 2008 CZECH MEDICAL ASSOCIATION J. E. PURKYNĚ |
Created by: NT Servis, s.r.o., hosted by P.E.S. consulting, s.r.o. |
WEBMASTER |