Perforation
of Jejunum by Plastic Biliary Stent after Injury Krška Z., Brůha R., Šváb J., Demeš R.,Votrubová J., Petrtýl J., Hořejš J. I. chirurgická, IV. interní a RD klinika VFN a UK v Praze |
|
Summary: The authors present case of patient with biliary stent dislocation after chest injury and fracture of VIII. rib.
Polymorbid patient with cirhosis, chronic pancreatitis, portal hypertension (Child Plugh B) and biliary stent
insertion came with acute abdominal pain and inflammatory signs. Progressive signs of acute abdomen have led
to laparotomy. Perforation of duodeno-jejunal-loop due to dislocated biliary stent, small loop adhesions and
thickened intestine wall were found. Postsurgical period was complicated with obstructive ileus, cholecystitis and
cholangoitis and the second biliary stent was inserted. Present-day status of the patient is satisfactory.
|
|