CZECH MEDICAL ASSOCIATION J. Ev. PURKYNĚ | |
Journals - Article | |
Česky / Czech version | Anest. neodkl. Péče, 11, 2000, No. 6, p. 255–258 |
General Anaesthesia with Laryngeal Mask Airway PAVLÍK M., BARTOŠÍK T., HŘIB R., NOHEL P., ŽÁK J. 1 1 Anesteziologicko-resuscitační klinika, Fakultní nemocnice u svaté Anny v Brně, přednosta doc. MUDr. Pavel Ševčík, CSc. |
|
Summary: Laryngeal mask airway represents a simple, effective and safe way to secure the airway during general anaesthesia. In the hands of an experienced
anaesthesiologist, its insertion is safe even in different positions of a patient. LMA can be used for both spontaneous and positive pressure ventilation.
The complication rate with LMA compared to standard tracheal intubation is not higher, and t he complications appear to be less critical.
|
|
Order this issue
|
BACK TO CONTENTS | ||
| HOME PAGE | CODE PAGE | CZECH VERSION | |
© 1998 - 2008 CZECH MEDICAL ASSOCIATION J. E. PURKYNĚ |
Created by: NT Servis, s.r.o., hosted by P.E.S. consulting, s.r.o. |
WEBMASTER |