Effect of Stopangin Spray on the Alcohol Level Assessed by the Analyzer
Alcotest 7410 of Dräger Co Zelený M., Mráz J., Pexa T., Mazura I. Ústav soudního lékařství Brno, |
|
Summary: During a check-up of a driver by a police patrol in the Czech Republic by means of a breath
analyzer of Dräger Co. an alcohol blood level of 0.50 g/kg was assessed. Later the driver reported
that before the test he used at 30- and 5- minute intervals the drug Stopangin spray. In the
Institute of Forensic Medicine the authors made an experiment which revealed that 22 minutes
after administration of the drug the apparatus gave a negative result. Agreement with these
conclusions was expressed also by a representative of Dräger Co. and the results were published
as an expert opinion with a recommended procedure for the police of the Czech Republic in the
South Moravian region.
|
|