CzMA JEP Home page CZECH MEDICAL ASSOCIATION J. Ev. PURKYNĚ
Journals - Article
CzMA JEP Home page News About Assocation Publishing Division Medical Journals Searching Supplements Catalogue
 
  Česky / Czech version Čes. Stomat., roč. 104, 2004, č. 1, s. 24–29.
 
Possibilities to Improve Primary Stability of Implant in Sinuslift 
Nathanský Z., Holakovský J. 

Stomatologická klinika 1. LF UK a VFN, Praha, přednosta prof. MUDr. J. Mazánek, DrSc. Subkatedra maxilofaciální chirurgie IPVZ, Praha, vedoucí prof. MUDr. J. Mazánek, DrSc.
 


Summary:

       The authors deal with the possibilities to extend indications for the application of so called primary sinuslift.A titanium splintwas developed, which brings about a substantial improvement of primary stability of implants in the sinuslift cavity and consequently a significant improvement in the results of these therapeutic procedures. The authors inform about the therapeutic procedure and their experience in the application of this method. The contribution is a part of the results of the Research Task IGA NK 6065-32000.

        Key words: primary sinuslift – implant stability – Ti splint
       

Order this issue

  BACK TO CONTENTS  
 
 
| HOME PAGE | CODE PAGE | CZECH VERSION |
©  1998 - 2008 CZECH MEDICAL ASSOCIATION J. E. PURKYNĚ
Created by: NT Servis, s.r.o., hosted by P.E.S. consulting, s.r.o.
WEBMASTER