CzMA JEP Home page CZECH MEDICAL ASSOCIATION J. Ev. PURKYNĚ
Journals - Article
CzMA JEP Home page News About Assocation Publishing Division Medical Journals Searching Supplements Catalogue
 
  Česky / Czech version Prakt. Lék., 2006, 86, No. 6, p. 328-330
 
Is mechanical valve iwplantation the best solution for patients with aortic valve disease?  
ČOČEK D., PAZDERKOVÁ R, SETINA M. 

Kardiochirurgické oddělení Nemocnice České Budějovice a.s., primář MUDr. Marek Setina, CSc.
 


Summary:

       Aortic valve replacement using a mechanical valve is a conventional proceduře for patients under 65 years of age but requires lifetime anticoagulation. The authors' question is whether this choice is appropriate and safe enough. Methods: Consecutive patients who had mechanical aortic valve replacement and were operated on between 2000 and 2003 in Departure of cardiac surgery at Hospital Ceske Budějovice, were followed up for one year. Results: Thirty day mortality was 2.9 %. Follow-up was completed on 98% patients. Late mortality was 4%. There were neither tromboembolic events nor bleeding during one year follow-up, but we noted two strokes of unclear origin and one case of prosthetic endocarditis. The symptomatology NYHA deereased from 2.36+0.91 to 1.13+0.45. Conclusion: Aortic valve replacement using mechanical valve is safe and related complications are acceptable.

        Key words: mechanical valve, aortic valve
       

Order this issue

  BACK TO CONTENTS  
 
 
| HOME PAGE | CODE PAGE | CZECH VERSION |
©  1998 - 2008 CZECH MEDICAL ASSOCIATION J. E. PURKYNĚ
Created by: NT Servis, s.r.o., hosted by P.E.S. consulting, s.r.o.
WEBMASTER