CZECH MEDICAL ASSOCIATION J. Ev. PURKYNĚ | |
Journals - Article | |
Česky / Czech version | Čes. Radiol., 56, 2002, No. 6, p. 327 - 330. |
New Trends of MR Imaging in Multiple Sclerosis. Our Experience with MR
Volumometry Using Local Software Vaněčková M.1, Seidl Z.1, Krásenský J.1, Obenberger J.1, Havrdová E.2, Viták T.1, Daneš J.1 Radiodiagnostická klinika 1. LF UK a VFN, Praha,1 přednosta doc. MUDr. Jan Daneš, CSc. Neurologická klinika 1. LF UK a VFN, Praha,2 přednostka prof. MUDr. Soňa Nevšímalová, DrSc. |
|
Summary: MR volumometry has become an important tool for monitoring chronic diseases of the central
nervous system including patients with multiple sclerosis (MS). A change in the total volume of
plaques (lesion load) during a defined time span is correlated with the clinical status according to
EDSS (Expanded Disability Status Scale). MR volumometry has been demonstrated on MR images
in the FLAIR modus. The lesion load has been calculated twice within the time span of one year
between two examinations. The recent approach of monitoring black holes on T1W images is
discussed together with the evaluation of brain atrophy. The authors’ own software has been used
with success. It has a high level of accuracy comparable with world centres of diagnostics and
monitoring of MS.
|
|
Order this issue
|
BACK TO CONTENTS | ||
| HOME PAGE | CODE PAGE | CZECH VERSION | |
© 1998 - 2008 CZECH MEDICAL ASSOCIATION J. E. PURKYNĚ |
Created by: NT Servis, s.r.o., hosted by P.E.S. consulting, s.r.o. |